Company Profile : |
Founded in 1994, United Orthopedics Corporation Manufactures orthopedic implants and precision medical devices. United Orthopedic Corporation is one of the few companies based in Asia that manufacture orthopedic implants and precision medical devices that meet the world quality standard.
In seven years, UOC has dedicated in orthopedic manufacturing and distribution for various joint replacement implants along with numerous surgical and orthopedic instruments.
Besides manufacture branded products, UOC also functions as an OEM Supplier for several multi-national surgical and orthopedic companies making appliances and implants for their label. Now we're the partners of many medical manufactories.
"Good Quality, Varity Products, Reasonable Price" are the beliefs of UOC. We believe the "Biotech-Magic" will be happened in Taiwan and UOC must be the one of them! |
|
Innovation Product: |
 |
The relationship of femoral size between proximal and distal diameter in most people is not proportional but wide distributed. According to Flare Index, the femur shape can be generally divided into three types, Stovepipe, Normal, and Champagne-Flute. To provide the best fill and fit femoral stem to each individual patient is always an important mission of implants manufacturer. Besides, how to maximize the sizes and minimize the inventories is the optimal goal.
United U2 Hip Stem System is based on a Matrix straight concept. There are fourteen sizes with eight different distal diameters and seven different proximal diameters which build a Matrix distribution. For patients with same distal femur size, the surgeons can choose different proximal sizes to obtain the maximum fill and fit; similarly, patients of similar proximal shape would then have choices of different distal diameter.
130' Neck Angle It is concluded from researches that the most suitable neck-shaft angle of hip stem is 125° to 134°. United U2 Hip Stem uses 130° neck angle which provides better range of motion. The 130° neck angle also increases hip stem offset that can effectively increase the moment arm of abductor muscles. By decreasing joint reaction force, patients will need less effort on walking, the possibility of limping will be reduced, and the wear debris of polyethylene will also be decreased to prevent osteolysis.
Polished Surface / Fluted Distal To avoid stress shielding and increase torsion stability, United U2 Hip Stem is designed with distal 2/5 Fluted and Polished Surface. It assures initial stability, reduces micro motion, and minimizes incidence of thigh pain. The distal stem of low stiffness can help maintain the load distribution through the proximal part of stem, thus ensures long-term fixation.Finite Element Analysis.
Performance of United U2 Hip Stem had been checked in the design stage with finite element analysis. The four different interface conditions are: 1. Fully Bonded; 2. Proximal Bonded; 3. Non-coated and 4. Proximal-Friction. The contact normal stress for United U2 Hip Stem is uniformly distributed. The Von Mises stress of U2-implanted femur is close to that of the intact femur, which implies that the stress shielding effect is less significant.
H.A Rough Surface Coating Hydroxyapatite coating is a proven method of surface treatment for bone induction. Researches have shown that coating on rough titanium surface is the best combination of surface treatment to maximize bone ingrowth. United U2 Hip Stem has a Ti base material plasma sprayed with commercial pure titanium powder to create rough surface and then coated with hydroxyapatite to ensure biological fixation. |
|